Agilis T - Ascential Test & Measurement
Detección de fugas y refrigeración HFC (non-flammable)

Agilis t

For CFC, HCFC, HFC and non-flammable blends on medium/high production rates using turbine flow-metering technology.

Turbine flow-metering technology Medium/high production rates with very accurate refrigerant dose Particularly suitable for charging several kilograms into air conditioners and big chillers Compatible with CFC, HCFC, HFC and non-flammable blends Evacuation capability Leak test capability Refrigerant charge capability Charging speed: up to 150 g/s for CFC, HCFC, HFC GEDA system integration Turbine flow-metering technology Medium/high production rates with very accurate refrigerant dose Particularly suitable for charging several kilograms into air conditioners and big chillers Compatible with CFC, HCFC, HFC and non-flammable blends Evacuation capability Leak test capability Refrigerant charge capability Charging speed: up to 150 g/s for CFC, HCFC, HFC GEDA system integration
Capacidades seleccionadas
Turbine flow-metering technology
Medium/high production rates with very accurate refrigerant dose
Particularly suitable for charging several kilograms into air conditioners and big chillers
Agilis T

Agilis T can be used in any type of cooling unit assembly line (refrigerators, deep freezers, air conditioners, etc.) and performs evacuation, leak tests, and refrigerant charges on medium to high production rate lines that require a very accurate refrigerant dose. Thanks to the turbine flow-metering device, it is particularly suitable for charging several kilograms of refrigerant into air conditioners and large chillers. Agilis works with all types of CFC, HCFC, HFC, and non-flammable blends.

Funciones clave

Turbine flow-metering technology
Medium/high production rates with very accurate refrigerant dose
Particularly suitable for charging several kilograms into air conditioners and big chillers
Compatible with CFC, HCFC, HFC and non-flammable blends
Evacuation capability
Leak test capability
Refrigerant charge capability
Charging speed: up to 150 g/s for CFC, HCFC, HFC
Integración del sistema GEDA

Especificaciones técnicas

Agilis T

Modelo N.º de inyectores N.º de sistema de dosificación
Agilis T11 1 1 turbine device
Agilis T22 2 2 turbine devices

Preguntas frecuentes

The Ascential T&M Agilis T is a refrigerant charging machine for cooling unit assembly lines (refrigerators, deep freezers, air conditioners, etc.) that performs evacuation, leak tests, and refrigerant charges on medium/high production rate lines. It uses turbine flow-metering technology and is particularly suitable for charging several kilograms of refrigerant into air conditioners and big chillers.

¿Listo para modernizar su infraestructura?

Contact our engineering team for a custom quote or technical consultation regarding Agilis t.

Solicitar un presupuesto

Elija su división:

Sentia AI

Asistente de chat

SentiaAI

¿Cómo puedo ayudarle hoy?

Complete el formulario siguiente para descargar su registro de chat.