Certus - Ascential Ensaio e Medição
Deteção de fugas e refrigeração HC (hidrocarbonetos)

Certus

Engineered to work with flammable gases and to be used in any type of cooling unit assembly lines, performs evacuation, leak tests and refrigerant charges.

Flammable gas compatible (HC, CFC, HCFC, HFC and flammable blends) Evacuation capability Leak test capability Refrigerant charge capability Dosing cylinder metering technology with special single-effect piston Small and medium production rates with very accurate refrigerant dose Charging speed: up to 40 g/s for HC Charging speed: up to 70 g/s for HFC Integração do sistema GEDA Flammable gas compatible (HC, CFC, HCFC, HFC and flammable blends) Evacuation capability Leak test capability Refrigerant charge capability Dosing cylinder metering technology with special single-effect piston Small and medium production rates with very accurate refrigerant dose Charging speed: up to 40 g/s for HC Charging speed: up to 70 g/s for HFC Integração do sistema GEDA
Capacidades Selecionadas
Flammable gas compatible (HC, CFC, HCFC, HFC and flammable blends)
Evacuation capability
Leak test capability
Certus

Engineered to work with flammable gases and for use in any type of cooling unit assembly line (refrigerators, deep freezers, air conditioners, etc.), Certus performs evacuation, leak tests, and refrigerant charges. It is particularly suited for small and medium production rates that require a very accurate refrigerant dose. Thanks to the dosing cylinder metering technology (featuring a special single-effect piston), the system precisely controls the filling amount from the beginning to the end of the injection phase.

CERTUS T is particularly suited for large charges of flammable gases (R290, R32, R600) at a small to medium cadence and uses a volumetric turbine flow meter with special sensors (temperature + pressure) to control the volume and mass in real time during the injection phase.

Certus charges all types of HC, CFC, HCFC, HFC, and other flammable blends.

Charging speed: up to 40 g/s for HC; up to 70 g/s for HFC.

Principais Recursos

Flammable gas compatible (HC, CFC, HCFC, HFC and flammable blends)
Evacuation capability
Leak test capability
Refrigerant charge capability
Dosing cylinder metering technology with special single-effect piston
Small and medium production rates with very accurate refrigerant dose
Charging speed: up to 40 g/s for HC
Charging speed: up to 70 g/s for HFC
Integração do sistema GEDA

Especificações técnicas

Certus

Modelo N.º de injetores N.º de sistema de dosagem
Certus C11 1 1 cylinder
Certus C12 1 2 cylinders

Perguntas Frequentes

The Ascential T&M Certus is a refrigerant charging machine engineered to work with flammable gases and used in cooling unit assembly lines (refrigerators, deep freezers, air conditioners, etc.). It performs evacuation, leak tests, and refrigerant charges, and is particularly suited for small and medium production rates requiring very accurate refrigerant dosing.

Pronto para modernizar a sua infraestrutura?

Contact our engineering team for a custom quote or technical consultation regarding Certus.

Obtenha um Orçamento

Escolha a sua divisão:

Sentia AI

Assistente de chat

SentiaAI

Como posso ajudá-lo hoje?

Preencha o formulário abaixo para descarregar o seu registo de conversa.