Section Valve Test System | Ascential T&M
Fluidotecnica Valvole

Prova dei distributori componibili

Ascential (formerly Titan) Section Valve Test system for fluid power valves applications. Sectional valves consist of multiple sections assembled together to form a stack to be used in mobile applications. A typical stack consists of 2 to 10 sections with each section being selected for a specific function. Sections consist of a directional control spool with or without a float position, proportionally actuated mechanically, hydraulically, or electrically. Sections may include workport reliefs, PO checks, pre or post pressure comp and flow limiters. Sections may utilize a load sense feature for pump control or be of an open center design for use with positive displacement pumps. Ascential (formerly Titan) has taken two approaches to test sectional valves. In one approach, the section is tested alone and then a very simple test is performed on the complete stack. A second approach is to perform section level testing after assembled into the stack.

Campo di pressione 10–350 BAR Campo di portata 0–350 LPM Cambio formato rapido Comunicazione CAN Compatibile con tutti i tipi di azionamento Flussometri e trasduttori di pressione integrati Capacità di rilevare micro perdite e prova simultanea delle perdite Routine di taratura automatizzate Portata in funzione del segnale Isteresi Portata in funzione della pressione (carico) Cadute di pressione Perdite Funzionalità Load Sense Impostazione della pressione di pilotaggio Risposta Contaminazione Campo di pressione 10–350 BAR Campo di portata 0–350 LPM Cambio formato rapido Comunicazione CAN Compatibile con tutti i tipi di azionamento Flussometri e trasduttori di pressione integrati Capacità di rilevare micro perdite e prova simultanea delle perdite Routine di taratura automatizzate Portata in funzione del segnale Isteresi Portata in funzione della pressione (carico) Cadute di pressione Perdite Funzionalità Load Sense Impostazione della pressione di pilotaggio Risposta Contaminazione
Portata in funzione del segnale Isteresi Portata in funzione della pressione (carico) Cadute di pressione Perdite Funzionalità Load Sense Impostazione della pressione di pilotaggio Risposta Contaminazione Portata in funzione del segnale Isteresi Portata in funzione della pressione (carico) Cadute di pressione Perdite Funzionalità Load Sense Impostazione della pressione di pilotaggio Risposta Contaminazione
Funzionalità principali
Campo di pressione 10–350 BAR
Campo di portata 0–350 LPM
Cambio formato rapido
Prova dei distributori componibili

Sectional valves consist of multiple sections assembled together to form a stack to be used in mobile applications.

I distributori componibili sono costituiti da più sezioni assemblate a formare un pacco da utilizzare in applicazioni mobili. Un pacco tipico comprende da 2 a 10 sezioni, ciascuna scelta per una funzione specifica. Le sezioni comprendono un cursore di controllo direzionale, con o senza posizione flottante, azionato in modo proporzionale per via meccanica, idraulica o elettrica. Le sezioni possono includere limitatrici di pressione sulle bocche di lavoro, valvole di non ritorno pilotate (PO check), compensatori di pressione a monte o a valle e limitatori di portata. Le sezioni possono sfruttare una funzione load sense per il controllo della pompa oppure essere a centro aperto, per l’impiego con pompe volumetriche.

Ascential (formerly Titan) has taken two approaches to test sectional valves. In one approach, the section is tested alone and then a very simple test is performed on the complete stack. A second approach is to perform section level testing after assembled into the stack. The approach is usually governed by the customer, although Ascential (formerly Titan) can discuss the pros and cons of each.

Caratteristiche principali

Campo di pressione 10–350 BAR
Campo di portata 0–350 LPM
Cambio formato rapido
Comunicazione CAN
Compatibile con tutti i tipi di azionamento
Flussometri e trasduttori di pressione integrati
Capacità di rilevare micro perdite e prova simultanea delle perdite
Routine di taratura automatizzate
Portata in funzione del segnale
Isteresi
Portata in funzione della pressione (carico)
Cadute di pressione
Perdite
Funzionalità Load Sense
Impostazione della pressione di pilotaggio
Risposta
Contaminazione

Prove e misure

Portata in funzione del segnale
Isteresi
Portata in funzione della pressione (carico)
Cadute di pressione
Perdite
Funzionalità Load Sense
Impostazione della pressione di pilotaggio
Risposta
Contaminazione

Dati tecnici

Campo di pressione

10–350 BAR

Campo di portata

0–350 LPM

Domande frequenti

Il sistema di collaudo per distributori componibili Ascential T&M è progettato per applicazioni su valvole di fluidotecnica. I distributori componibili sono costituiti da più sezioni assemblate a formare un pacco utilizzato in applicazioni mobili; un pacco tipico comprende da 2 a 10 sezioni, ciascuna scelta per una funzione specifica.

È pronto ad aggiornare la Sua infrastruttura?

Per un preventivo personalizzato o una consulenza tecnica sulla prova dei distributori componibili, contatti il nostro ufficio tecnico.

Richiedi un preventivo

Scegli la divisione:

Sentia AI

Assistente chat

SentiaAI

Come posso aiutarLa oggi?

Compili il modulo sottostante per scaricare il registro della chat.